Configuring The Ppp Clear Loop Detected Timer; Configuring Dynamic Profiles For Ppp - Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual

Network interfaces configuration
Table of Contents

Advertisement

JUNOS 10.1 Network Interfaces Configuration Guide
user@host> run show interfaces t1-0/0/0:1:1.0 detail

Configuring the PPP Clear Loop Detected Timer

When a Point-to-Point Protocol (PPP) session detects a loop, the loop detected flag
is set. If the flag is not cleared by the protocol after the loopback is cleared, the clear
loop detected timer clears the flag after the specified time has elapsed.
To configure the clear loop detected timer for the LCP component of a PPP session,
include the
You can include this statement at the following hierarchy levels:
To monitor the configuration, issue the
command.

Configuring Dynamic Profiles for PPP

A dynamic profile acts as a template that enables you to create, update, or remove
a configuration that includes attributes for client access (for example, interface or
protocol) or service (for example, IGMP). Using these profiles you can consolidate all
of the common attributes of a client (and eventually a group of clients) and apply
the attributes simultaneously.
After they are created, the profiles reside in a profile library on the router. You can
then use the
dynamic profile to a PPP interface, you can include the
the
To monitor the configuration, issue the
For information about dynamic profiles, see Dynamic Profiles Overview in the JUNOS
Subscriber Access Configuration Guide.
174
Configuring the PPP Clear Loop Detected Timer
Logical interface t1-0/0/0:1:1.0 (Index 67) (SNMP ifIndex 40)
(Generation 156)
Flags: Hardware-Down Device-Down Point-To-Point SNMP-Traps 0x4000
Encapsulation: PPP
PPP parameters:
LCP restart timer: 2000 msec
NCP restart timer: 2000 msec
Protocol inet, MTU: 1500, Generation: 163, Route table: 0
Flags: Protocol-Down
Addresses, Flags: Dest-route-down Is-Preferred Is-Primary
Destination: 1.1.1/24, Local: 1.1.1.2, Broadcast: 1.1.1.255,
loopback-clear-timer
loopback-clear-timer seconds;
[edit interfaces interface-name unit logical-unit-number ppp-options]
[edit logical-systems logical-system-name interfaces interface-name unit
logical-unit-number ppp-options]
dynamic-profile
[edit interfaces interface-name unit logical-unit-number ppp-options]
[edit interfaces interface-name unit logical-unit-number ppp-options]
dynamic-profile profile-name;
statement, and specify the number of seconds.
show interfaces interface-name extensive
statement to attach profiles to interfaces. To assign a
show interfaces interface-name
dynamic-profile
statement at
hierarchy level:
command.