6.1.2
Interpreting the MECHATROLINK-III Common Parameter
List
The types of motors to which the parameter applies.
All: The parameter is used for both Rotary Servomotors and Linear Servomotors.
Rotary: The parameter is used for only Rotary Servomotors.
Linear: The parameter is used for only Linear Servomotors.
Rotary Servomotor terms are used for parameters that are
applicable to all Servomotors. If you are using a Linear Servomotor,
you need to interpret the terms accordingly. Refer to the following
section for details.
Parameter
Size
No.
61
4
PnAC2

6.1.2 Interpreting the MECHATROLINK-III Common Parameter List

Differences in Terms for Rotary Servomotors and
Linear Servomotors on page x
Setting
Name
Range
1,000 to
Speed Loop Gain
2,000,000
6.1 Interpreting the Parameter Lists
Indicates when a change to the
parameter will be effective.
"After restart" indicates parameters
that will be effective after one of the
following is executed.
• The power supply is turned OFF
and ON again.
• The Setup Device command (CON-
FIG) is sent.
• A software reset is executed.
Setting Unit
Default
Applicable
[Resolution]
Setting
Motors
0.001 Hz
40000
[0.1 Hz]
You can set the parameter in increments of
the setting unit.
However, if a unit is given in square brackets,
the setting is automatically converted to the
resolution given in the square brackets.
When
Classi-
Enabled
fication
Immedi-
All
Tuning
ately
6
6-3