Enabling Information Output To The Snmp - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Manual – Information Center
H3C S7500 Series Ethernet Switches
To do...
Enable
information output
to the trap buffer
Define an
information
source
Set the format of
time stamp
Note:
To view debugging information of specific modules, you need to set the information
type to debug in the info-center source command, and enable debugging on
corresponding modules using the debugging command as well.

1.2.6 Enabling Information Output to the SNMP

Follow these steps to enable information output to the SNMP:
To do...
Enter system view
Enable the
information center
Enable
information output
to the SNMP
Use the command...
info-center trapbuffer
[channel { channel-number |
channel-name } | size
buffersize]*
info-center source
{ modu-name | default }
channel { channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
info-center timestamp { log |
trap | debugging } { boot |
date | none }
Use the command...
system-view
info-center enable
info-center snmp
channel
{ channel-number |
channel-name }
1-12
Chapter 1 Information Center
Remarks
Optional
By default, the switch uses
information channel 3 to
output trap information to the
trap buffer, which can holds
up to 256 items by default.
Required
Optional
This is to set the time stamp
format for
log/debugging/trap
information output.
This determines the time
stamp viewable to users.
Remarks
Optional
By default, the information center is
enabled.
Required
By default, the switch outputs trap
information to SNMP through
channel 5.

Advertisement

Table of Contents
loading