Rrpp On H3C S7500 Series Ethernet Switches - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Mannual – RRPP
H3C S7500 Series Ethernet Switches
III. Intersectant ring networking
Master node
Transit node
Figure 1-4 Intersectant ring networking
There are two or more rings in the network topology and two common nodes exist
between each pair of rings. In this case, only one RRPP domain is to be defined, in
which one ring must be defined as the primary ring and the rest as subrings.

1.1.5 RRPP on H3C S7500 Series Ethernet Switches

To employ RRPP on an S7500 series Ethernet switch, make sure that:
The chassis comes with the silk print XGbus.
For H3C S7503/S7506/S7506R switches, Salience III series SRPUs (including
Salience III, Salience III Plus, and Salience III Edge) are used. Besides, BootROM
version 527 (or later) is used.
For H3C S7502 switches, the CPLD version of the SRPU is not lower than 005.
The CPLD version of the LPUs is not lower than 005.
Ports that support RRPP are:
The four Gigabit SFP ports on Salience III Edge/ Salience III engine
Gigabit SFP ports/10 Gigabit ports on LS81T12PE, LS81P12TE, LS81GP8UB,
LS81TGX2, LS81TGX4, LS81T32P, LS81T16P, and LS81GP48 LPUs.
Domain 1
Switch A
Switch B
Ring 1
Switch C
Switch D
Assistant edge node
1-7
Chapter 1 RRPP Configuration
E
dge node
Master node
Ri
ng 2
Switch E

Advertisement

Table of Contents
loading

Table of Contents