Configuring The Timers Of Tacacs Servers; Displaying And Maintaining Aaa & Radius & Hwtacacs Information - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Manual – AAA & RADIUS & HWTACACS & EAD
H3C S7500 Series Ethernet Switches

1.5.7 Configuring the Timers of TACACS Servers

Table 1-29 Configure the timers of TACACS servers
Enter system view
Create a HWTACACS
scheme and enter its view
Set the response timeout
time of TACACS servers
Set the wait time for the
primary server to restore
the active state
Set the real-time
accounting interval
Caution:
The setting of real-time accounting interval is indispensable to real-time accounting.
After an interval value is set, the device transmits the accounting information of
online users to the TACACS accounting server at intervals of this value. Even if the
server does not respond, the device does not disconnect the online user.
The interval must be a multiple of 3.
The setting of real-time accounting interval somewhat depends on the performance
of the device and the TACACS server: A shorter interval requires higher device
performance.
1.6 Displaying and Maintaining AAA & RADIUS &
HWTACACS Information
After the above configurations, you can execute the display commands in any view to
display the operation information about AAA, RADIUS, and HWTACACS, so as to
verify your configuration.
To do...
system-view
hwtacacs scheme
hwtacacs-scheme-name
timer response-timeout
seconds
timer quiet minutes
timer
realtime-accounting
minutes
Chapter 1 AAA & RADIUS & HWTACACS
Use the command...
1-38
Configuration
Remarks
Required
By default, no
HWTACACS scheme
exists.
Optional
By default, the response
timeout time is five
seconds.
Optional
By default, the primary
server waits five minutes
before restoring the active
state.
Optional
By default, the real-time
accounting interval is 12
minutes.

Advertisement

Table of Contents
loading

Table of Contents