I. Configuration procedure (in system view)
Follow these steps to configure a port as an edge port (in system view):
To do ...
Enter system view
Configure the
specified ports as
edge ports
II. Configuration procedure (in Ethernet port view)
Follow these steps to configure a port as an edge port (in Ethernet port view):
To do ...
Enter system view
Enter Ethernet port
view
Configure the port
as an edge port
On a switch with BPDU guard not enabled, an edge port becomes a non-edge port
again once it receives a BPDU from another port.
Note:
You are recommended to configure the Ethernet ports connected directly to terminals
as edge ports and enable the BPDU guard function as well. This not only enables these
ports to transit to forwarding state rapidly but also secures your network.
III. Configuration example
# Configure Ethernet2/0/1 as an edge port.
1)
Configure in system view.
<H3C> system-view
[H3C] stp interface ethernet2/0/1 edged-port enable
2)
Configure in Ethernet port view.
<H3C> system-view
[H3C] interface ethernet2/0/1
Use the command ...
system-view
stp interface interface-list
edged-port enable
Use the command ...
system-view
interface interface-type
interface-number
stp edged-port enable