Displaying And Maintaining Gvrp - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Manual – GVRP
H3C S7500 Series Ethernet Switches
Table 1-2 Relations between the timers
Timer
Hold
Join
Leave
LeaveAll
Note:
The recommended settings of GARP timers:
GARP Hold timer: 100 centiseconds (1 second).
GARP Join timer: 600 centiseconds (6 seconds).
GARP Leave timer: 3000 centiseconds (30 seconds).
GARP LeaveAll timer: 12000 centiseconds (2 minutes).

1.3 Displaying and Maintaining GVRP

Display GARP statistics
Display the settings of the
GARP timers
Display GVRP statistics
Display the global GVRP
status
Lower threshold
10 centiseconds
This lower threshold is greater
than or equal to twice the timeout
time of the Hold timer. You can
change the threshold by changing
the timeout time of the Hold timer.
This lower threshold is greater
than twice the timeout time of the
Join timer. You can change the
threshold by changing the timeout
time of the Join timer.
This lower threshold is greater
than the timeout time of the Leave
timer. You can change threshold
by changing the timeout time of
the Leave timer.
To do...
display garp statistics [ interface
interface-list ]
display garp timer [ interface
interface-list ]
display gvrp statistics [ interface
interface-list ]
display gvrp status
This upper threshold is less than
or equal to one-half of the timeout
time of the Join timer. You can
change the threshold by changing
the timeout time of the Join timer.
This upper threshold is less than
one-half of the timeout time of the
Leave timer. You can change the
threshold by changing the timeout
time of the Leave timer.
This upper threshold is less than
the timeout time of the LeaveAll
timer. You can change the
threshold by changing the timeout
time of the LeaveAll timer.
32,765 centiseconds
Use the command...
1-6
Chapter 1 GVRP Configuration
Upper threshold
Remarks
Available in
any view.

Advertisement

Table of Contents
loading

Table of Contents