Master Node Configuration; Master Node Configuration Tasks - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Mannual – RRPP
H3C S7500 Series Ethernet Switches
Note:
For information about the chassis, SRPU, and LPU of H3C S7503/S7506/S7506R
series Ethernet switches, refer to H3C S7500 Series Ethernet Switches Installation
Manual.
For information about the chassis, SRPU, and LPU of H3C S7502 Ethernet switch,
refer to H3C S7502 Ethernet Switch Installation Manual.
As for the above-mentioned ports, to make RRPP-related configuration to take effect,
you need also to make sure that:
The ports are Trunk ports and permit packets of data VLANs.
The ports cannot be aggregation ports.
MSTP, QinQ, 802.1X or Voice VLAN is not enabled on the ports.

1.2 Master Node Configuration

1.2.1 Master Node Configuration Tasks

Follow these steps to configure the master node:
To do...
Enter system view
Create an RRPP
domain, and enter
RRPP domain view
Specify a control
VLAN for the RRPP
domain
Specify the current
switch as the primary
node of a ring, and
specify the primary
port and the
secondary port of the
node
Configure RRPP
domain timers
Enable an RRPP ring
Use the command...
system-view
rrpp domain domain-id
control-vlan vlan-id
ring ring-id node-mode
master [ primary-port
pri-port ] [ secondary-port
sec-port ] level level-value
timer hello-timer
hello-value fail-timer
fail-value
ring ring-id enable
1-8
Chapter 1 RRPP Configuration
Remarks
Required.
The command prompt of
RRPP domain view
depends on the domain-id
you input.
Required
Required.
Level 0 identifies the primary
ring and level 1 identifies a
subring.
Optional.
By default, the Hello timer is
set to 1 second, and the Fail
timer to 3 seconds.
Required

Advertisement