Dc Output Alarm Threshold Configuration; Dc Output Alarm Thresholds Configuration Tasks; Dc Output Alarm Threshold Configuration Example - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Manual – PoE
H3C S7500 Series Ethernet Switches
[H3C] display poe-power ac-input state

2.3 DC Output Alarm Threshold Configuration

You can set the DC output alarm thresholds for the PoE PSUs to enable the S7500
series to monitor the DC output voltages of the PSUs in real time through SRPUs.

2.3.1 DC Output Alarm Thresholds Configuration Tasks

Follow these steps to set DC output alarm thresholds:
Enter the system view
Set the overvoltage alarm
threshold of DC output
(upper threshold) for the
PoE PSUs
Set the undervoltage
alarm threshold of DC
output (lower threshold)
for the PoE PSUs

2.3.2 DC Output Alarm Threshold Configuration Example

I. Network requirements
Set the overvoltage alarm threshold of DC output for the PoE PSUs to 55.0 V.
Set the undervoltage alarm threshold of DC output for the PoE PSUs to 47.0 V.
II. Configuration procedure
# Enter system view.
<H3C> system-view
# Set the overvoltage alarm threshold of DC output for the PoE PSUs to 55.0 V.
[H3C] poe-power output-thresh upper 55.0
# Set the undervoltage alarm threshold of DC output for the PoE PSUs to 47.0 V.
[H3C] poe-power output-thresh lower 47.0
# Display the DC output state of the PoE PSUs.
[H3C] display poe-power dc-output state
# Display the DC output voltage/current values of the PoE PSUs.
[H3C] display poe-power dc-output value
To do...
system-view
poe-power
output-thresh upper
string
poe-power
output-thresh lower
string
Chapter 2 PoE PSU Supervision Configuration
Use the command...
2-3
Remarks
Required
You are recommended to
set the upper threshold to
47 V when 220 VAC or
110 VAC is input.
Required
You are recommended to
set the lower threshold to
55 V when 220 VAC or
110 VAC is input.