Operation Manual – SNMP and RMON
H3C S7500 Series Ethernet Switches
To do...
Add an alarm entry
Add an extended
alarm entry
Enter Ethernet port
view
Add a history entry
Add a statistics entry
Note:
The rmon alarm and rmon prialarm commands take effect on existing nodes only.
For each port, only one RMON statistics entry can be created. That is, if an RMON
statistics entry is already created for a given port, creation of another entry with a
different index for the same port will not succeed.
Use the command...
rmon alarm entry-number
alarm-variable sampling-time
{ delta | absolute } rising
threshold threshold-value1
event-entry1 falling threshold
threshold-value2 event-entry2
[ owner text ]
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-timer { delta |
absolute | changeratio }
rising_threshold
threshold-value1 event-entry1
falling_threshold
threshold-value2 event-entry2
entrytype { forever | cycle
cycle-period } [ owner text ]
interface interface-type
interface-number
rmon history entry-number
buckets number interval
sampling-interval [ owner text ]
rmon statistics entry-number
[ owner text ]
2-4
Chapter 2 RMON Configuration
Remarks
Optional
Before adding an alarm
entry, you need to use the
rmon event command to
define the event
referenced by the alarm
entry.
Optional
Before adding an
extended alarm entry, you
need to use the rmon
event command to define
the event referenced by
the extended alarm entry.
Optional
Optional