H3C S7500 Series Operation Manual page 855

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Manual – FTP and TFTP
H3C S7500 Series Ethernet Switches
Configure the IP address 1.1.1.1 for a VLAN interface on the switch, and 2.2.2.2
for the PC. Ensure that the switch and the PC are reachable to each other.
The switch application named switch.bin is stored on the PC. Upload it to the FTP
server through the FTP to upgrade the application of the switch, and download the
switch configuration file named config.cfg from the switch to backup the configuration
file.
II. Network diagram
Switch
Switch
Figure 1-2 Network diagram for FTP configurations
III. Configuration procedure
1)
Configure the switch
# Log in to the switch. (You can log into a switch through the Console port or by Telnet.
See the Login part of this manual for detailed information.)
<H3C>
# Start the FTP service on the switch and create a user account and the corresponding
password.
<H3C> system-view
[H3C] ftp server enable
[H3C] local-user switch
[H3C-luser-switch] password simple hello
[H3C-luser-switch] service-type ftp ftp-directory flash:/
2)
Run an FTP client application on the PC to connect to the FTP server. Upload the
application named switch.bin to the root directory of the Flash memory of the FTP
server, and download the configuration file named config.cfg from the FTP server.
Take the command line window tool provided by Windows for example.
# Enter the command line window and switch to the directory where the file switch.bin is
located. Assume that the file resides in C:\.
C:\>
# Access the Ethernet switch through FTP. Enter the user name "switch" and password
"hello" to log in and enter FTP view.
C:\> ftp 1.1.1.1
Network
Network
Network
Network
PC
PC
1-5
Chapter 1 FTP and TFTP Configuration

Advertisement

Table of Contents
loading