Operation Manual – Port Basic Configuration
H3C S7500 Series Ethernet Switches
Chapter 1 Port Basic Configuration
When configuring port basic configuration, go to these sections for information you are
interested in:
Ethernet Port Configuration
Ethernet Port Configuration Example
Troubleshooting Ethernet Port Configuration
1.1 Ethernet Port Configuration
1.1.1 Initially Configuring a Port
To do...
Enter system view
Enter Ethernet port
view
Enable the Ethernet
port
Set the description
of the Ethernet port
Set the duplex mode
of the Ethernet port
Set the speed of the
Ethernet port
Set the medium
dependent interface
(MDI) attribute of the
Ethernet port
Allow jumbo frames
to pass through the
Ethernet port
Use the command...
system-view
interface interface-type
interface-number
undo shutdown
description text
duplex { auto | full | half }
speed { 10 | 100 | 1000 |
10000 | auto }
mdi { across | auto |
normal }
jumboframe enable
[ jumboframe-value ]
1-1
Chapter 1 Port Basic Configuration
Remarks
—
—
Optional
By default, the port is enabled.
Use the shutdown command
to disable the port.
Optional
By default, no description is
defined for the port.
Optional
By default, the duplex mode of
the port is auto
(auto-negotiation).
Optional
By default, the speed of the
port is auto (auto-negotiation).
Optional
Be default, the MDI attribute of
the port is auto.
Optional
By default, jumbo frames that
are larger than 1518 bytes and
smaller than 1536 bytes are
allowed to pass through the
port.