Mstp Configuration - H3C S7500 Series Operation Manual

Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Operation Manual – MSTP
H3C S7500 Series Ethernet Switches
To do ...
Specify whether or
not the link
connected to the
port is a
point-to-point link
Note:
Among aggregated ports, you can configure only the links of master ports as
point-to-point links. If an auto-negotiating port operates in full duplex mode after
negotiation, you can configure the link of the port as a point-to-point link.
After you configure the link of a port as a point-to-point link, the configuration applies to
all MSTIs. If the actual physical link of a port is not a point-to-point link and you forcibly
configure the link as a point-to-point link, temporary loops may be incurred.
III. Configuration example
# Configure the link connected to Ethernet2/0/1 as a point-to-point link.
1)
Configure in system view.
<H3C> system-view
[H3C] stp interface ethernet2/0/1 point-to-point force-true
2)
Configure in Ethernet port view.
<H3C> system-view
[H3C] interface ethernet2/0/1
[H3C-Ethernet2/0/1] stp point-to-point force-true

1.2.13 MSTP Configuration

I. Configuration procedure
Follow these steps to enable/disable MSTP in system view:
Use the command ...
stp point-to-point
{ force-true | force-false |
auto }
1-22
Chapter 1 MSTP Configuration
Remarks
Required
The auto keyword is adopted
by default.
The force-true keyword
specifies that the link
connected to the port is a
point-to-point link.
The force-false keyword
specifies that the link
connected to the port is not a
point-to-point link.
The auto keyword specifies to
automatically determine
whether or not the link
connected to the port is a
point-to-point link.