Mechanical System - Siemens SIMODRIVE 611 universal Function Manual

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

4 Commissioning
4.10 Linear motors (1FN1, 1FN3 motors)
4.10.4

Mechanical system

Checking the
mounting
dimensions
and
air gap 1FN1
Table 4-10
Important mounting dimensions and air gap for 1FN1 motors
Important dimension to be checked
Mounting dimension e
[mm]
1
Mounting dimension e
[mm] (without thermal insulating strips)
2
Measurable air gap l [mm] (without taking into account the mounting
dimension tolerance)
Clearance b [mm] (without taking into account the mounting dimension
tolerance)
4-182
The mounting dimensions can be checked before mounting the motor,
e.g. using the final dimensions and feeler gauges.
The mounting dimensions must lie within the specified tolerance band-
width over the complete traversing distance.
Note
The valid mounting dimensions can be taken from the following
literature:
S
Reference:
//PJLM/
S
The data sheet of the appropriate motor
For mounting dimension and air gap, the following applies:
Only the mounting dimension is decisive and not the air gap which can
be measured, when it comes to maintaining the electrical and
system–related characteristics of the linear motor. The air gap must be
large enough so that the motor can freely move.
Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö
Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö
e
2
e
1
b
Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö
Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö Ö
Fig. 4-14 Important dimensions when mounting 1FN1 motors
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Configuration Manual
1FN1, 1FN3 Linear Motors
l
Linear motors
1FN1 07j
80.7 $ 0.3
76.7 $ 0.3
+0.3
1.1
/
–0.45
13 $ 1
E Siemens AG 2005 All Rights Reserved
08.01
01.99
Thermal
insulation
strips
1FN1 ...
1FN1 12j
1FN1 18j
1FN1 24j
106.7 $ 0.3
101.7 $ 0.3
+0.3
1.1
/
–0.45
13 $ 1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents