The subscribers evaluate the broadcast telegrams, sent from the pu-
blishers, and use the data which has been received as setpoints.
The setpoints are used, in addition to the setpoints received from the
master, corresponding to the configured telegram structure (P0915).
Links and taps
The links configured in the subscriber (connection to publisher) contain
the following information:
S
S
S
Several taps are possible within a link. Several input data or input data
areas, which are not associated with one another, can be used as set-
point via a tap.
Links are possible to the device itself. This means, e.g. that for a two–
axis module, data can be transferred from drive A to B. This internal
link corresponds, as far as the timing is concerned, to a link via
PROFIBUS.
Prerequisites and
The following limitations should be observed for the "slave–to–slave"
limitations
communications function:
S
S
S
S
S
S
S
Applications
For example, the following applications can be implemented using the
"slave–to–slave communications" function:
S
S
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
5.10 Slave–to–slave communications (from SW 4.1)
From which publishers may input data be received?
Which input data is there?
A which location should the input data be used as setpoints?
Drive ES Basic V5.1 SP1
Optional PROFIBUS–DP2 module w SW 4.1
Optional PROFIBUS–DP3 module w SW 4.1
SIMODRIVE 611 universal
Number of process data
Number of links to publishers
Number of taps per link
Axis couplings (this is practical for clock cycle synchronous
operation) (refer to Chapter 6.3)
– Angular synchronism where the position reference value or posi-
tion actual value is entered
– Torque setpoint coupling (master/slave operation)
Master drive
Closed–loop speed controlled
Entering digital input signals from another slave (refer to Chapter
5.10.4)
5 Communications via PROFIBUS DP
w SW 4.1
max. of 16 per drive
max. 3 and 1 internal
max. 8
<––>
Slave drive
Open–loop torque controlled
5
5-315