A.1
Parameter list
1107
Transistor limiting current
Min
Standard
... specifies the maximum transistor limiting current of the power section as peak value.
Important:
This parameter is used as normalization basis for the current actual value sensing.
Note: refer to the index entry "Power section currents"
1108
Limiting current, power section (RMS)
Min
Standard
before SW 2.4, the following is valid:
... displays the limiting current of the power section (I-max in A RMS) at the selected pulse fre-
quency (P1100).
from SW 2.4 the following is valid:
... displays the power section limiting current (I max in A RMS) for the standard pulse frequency
setting (P1100). The reduction factor for higher pulse frequencies is displayed in P1099.
Note: refer to the index entry "Power section currents"
1109
Limiting current, power section S6 (RMS)
Min
Standard
before SW 2.4, the following is valid:
... displays the limiting current of the power section in S6 duty (I-S6 in A RMS) at the selected
pulse frequency (P1100).
from SW 2.4 the following is valid:
... displays the power section limiting current in S6 duty (I-S6 in A RMS) for the standard pulse
frequency setting (P1100). The reduction factor for higher pulse frequencies is displayed in
P1099.
Note: refer to the index entry "Power section currents"
1110
Power section version
Min
Standard
... displays which power section was identified at run-up.
0
Power section without automatic identification
> 0
Power section with automatic identification
The code of the identified power section is in P1110 and must coincide with the code entered
into P1106 (power section code number).
Note: Assignment, power module code number, refer to P1106
A-814
Max
Unit
A(pk)
Max
Unit
A(rms)
Max
Unit
A(rms)
Max
Unit
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Floating Point
RO
Data type
Effective
Floating Point
RO
Data type
Effective
Floating Point
RO
Data type
Effective
Unsigned16
RO
E Siemens AG 2005 All Rights Reserved
04.05
01.99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents