Siemens SIMODRIVE 611 universal Function Manual page 625

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
Operator control,
When a fault occurs, it can be handled using the MINUS and P keys as
if a fault is present
shown in the following diagram.
Code for a fault
(E and 1 hyphen)
Display and
operator unit
Automatically
after one
minute
+
P
Key
Key
Fig. 7-1
Operator control, if a fault is available
Operator control,
When faults occur, they can be handled as shown in the following dia-
if several faults
gram using the PLUS, MINUS and P keys.
have occurred
Code for the first fault which
occurred
(E and 3 hyphens)
Display and
operator unit
Automatically
after one
minute
+
P
Key
Key
Key
Fig. 7-2
Handling several faults
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
7.2
Displaying and handling faults and warnings
Switch into the parameterizing mode
Acknowledging faults with RESET FAULT MEMORY
P
Alarm mode
Flashing
display
Displays additional faults, sorted according to the sequence
+
that they occurred
Switch into the parameterizing mode
Acknowledging faults with RESET FAULT MEMORY
P
7 Fault Handling/Diagnostics
Alarm mode
Flashing
display
Acknowledge
and
P
term. 65.x
de–energized
Parameterizing mode
Code for an additional fault (E
and 2 hyphens)
+
+
Parameterizing mode
...
Acknowledge
P
and
term. 65.x
de–energized
7-625