Teach-In (From Sw 4.1) - Siemens SIMODRIVE 611 universal Function Manual

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
02.02
! not 611ue !
6.13
Teach–in (from SW 4.1)
Description
Using this function, an approached axis position can be directly entered
into a specific traversing block as position reference value.
The axis can be traversed to the required position e.g. using "jogging"
and/or "incremental jogging.
The "teach–in" function is activated using the "activate teach–in (edge)"
input signal in the "positioning" mode.
It is not possible to activate "teach–in" while a traversing program is
running.
Table 6-70
Overview of teach–in
Question?
Parameters
Teach–in block
In which tra-
In which tra-
P0120 = –1
versing block is
(Standard)
the position
value be writ-
value be writ-
P0120 w 0
ten?
Teach–in standard block
P0121 = –1
(Standard)
How does the
teach–in block
teach–in block
become a com-
become a com-
P0121 w 0
plete traversing
block?
Teach–in configuration
P0124.0 = 1
What are the
various config-
uration possi-
bilities?
bilities?
P0124.1
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The position value (actual position reference value) is written into the
traversing block which is selected either via digital input signals (Fct.
No. 50 to 55) or the PROFIBUS control signal SatzAnw.0 – .5.
The position value (actual position reference value) is written into the
traversing block which is specified using P0120.
When activating "Teach–in", only the position value is written into the
selected block (the actual position reference value).
All other data must be manually entered to make it a complete travers-
ing block.
For "teach–in", the block, defined using P0121, is transferred into the
selected block and the position value (actual position reference value)
is overwritten.
P0087 is not completely transferred, but only the position mode and the
block enable condition. Information as to whether the block is sup-
pressed or not is not transferred into the new block.
Automatically increase the block number (P0120 w 0)
In this mode, after each successful "teach–in", the teach–in block in
P0120 is automatically increased.
In this case, the teach in blocks are overwritten.
If the teach–in block is selected using an input signal (P0120 = –1) and
the "automatically increase block number" function is enabled, then the
following applies:
S
The first teach–in block is selected via input signals
S
Additional teach–in blocks are defined using P0120
The block number is automatically searched for
= 1: In this mode, for "teach–in", a search is made for the block in
P0120. If an invalid block is selected via P0120, then this
block is generated in the memory at the first position where there
is still no block. A complete block is generated
(although P0121 = –1).
= 0: If the block in P0120 or the block selected via the input signals
is not available, then fault 183 is output.
6 Description of the Functions
6.13 Teach–in (from SW 4.1)
Description
6
6-601

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents