Siemens SIMODRIVE 611 universal Function Manual page 447

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
4. The coupling is switched–out using the command COUPLING_OUT.
Master
v
LA
drive
(LA)
LA
Master drive
FA
Slave drive
Fig. 6-36 Application example: Coupling via an input terminal with queue functionality
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The drive remains stationary and the program is continued. From
this time onwards, there are no restrictions regarding the com-
mands.
The slave drive can be returned to the waiting position e.g. using an
additional command (POS ABS).
Traversing program in the slave drive
COUPLING IN ; wait until the next workpiece comes close
POS REL ; relative traversing motion
... blocks to be processed (i.e. for machining)
COUPLING OUT
POS ABS waiting position ; retraction to the waiting position
GOTO start
Synchronization
distance x
BERO
I0.x
FA
P0420
–s
0
6 Description of the Functions
6.3
Axis couplings (from SW 3.3)
P0412
Machining
distance
sync
Superimposed
motion
Slave
drive
(FA)
Waiting
position
s
6-447
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents