First Commissioning With Simocom U - Siemens SIMODRIVE 611 universal Function Manual

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
10.99
4.3.1

First commissioning with SimoCom U

Procedure when
When "SIMODRIVE 611 universal" is first commissioned using the
commissioning the
"SimoCom U" parameterizing and start–up tool, proceed as follows:
drive for the first
1. Power–up the drive group
time
2. Start SimoCom U
3. Request online operation for drive A
4. Execute the drive configuration, and at the end, press the "Calculate
5. Carry–out basic commissioning
Note
If drive B is to be commissioned, then the points must be executed for
drive B from point 3 onwards.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Operator action:
Execute the "Search for online drives" function in the "Start–up"
menu, and select drive A in the "Drive and dialog browser".
Is the "start–up required" window displayed?
– Yes: ––> Start the drive configuration assistant
––> This signals the drive the existing configuration (power mo-
dule, motor, etc.).
– No: ––> Press "re–configure drive" button
––> This adapts the control board to the present configuration
(power module, motor, etc.).
controller data, save, reset" button.
Set the "Drive and dialog browser" (lefthand window) to "Parameter".
To do this, press the "P Par" button below the browser.
The commissioning is now executed by working through the remain-
ing dialog boxes for this drive in the "Drive and dialog browser" from
the top to the bottom. The required settings are made in the se-
lected dialog boxes.
4 Commissioning
4.3
Commissioning via SimoCom U
4
4-121

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents