Siemens SIMODRIVE 611 universal Function Manual page 818

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
1141
Magnetizing reactance (ARM)
Min
Standard
0.0
0.0
1142
Threshold speed field weakening (ARM SRM)
Motor threshold speed for field weakening (SLM)
Min
Standard
0.0
0.0
0.0
0.0
1145
Stall torque reduction factor
Min
Standard
5.0
100.0
1146
Maximum motor speed (ARM SRM)
Maximum motor velocity (SLM)
Min
Standard
0.0
1500.0
0.0
0.0
0.0
0.0
... specifies the maximum motor speed/maximum motor velocity defined by the motor manufac-
turer.
Note:
Refer under the index entry "Limits"
1147
Speed limitation (ARM SRM)
Velocity limiting, motor (SLM)
Min
Standard
0.0
8000.0
0.0
120.0
0.0
7000.0
... specifies the maximum permissible motor speed or motor velocity (refer under the index
entry "Limits").
1148
Threshold speed stall power (ARM)
Min
Standard
The rated output is reduced from the "Threshold speed of the stall power".
1149
Reluctance torque constant (SRM)
Min
Standard
0.0
0.0
For synchronous motors with non-symmetrical rotors in the rotational axis, the additional reluc-
tance torque can be used to increase the torque.
The reluctance torque constant, multiplied by the torque- and field-generating current, gives the
torque increase due to the reluctance torque.
Note:
Refer to P1128 (optimum load angle)
Synchronous motors with non-symmetrical rotor in the rotational axis: e.g. 1FE motors
Traverse with reluctance torque: P1128 and P1149 not equal to the standard value
Traverse without reluctance torque: P1128 and P1149 equal to the standard value
1150
P gain flux controller (ARM)
Min
Standard
0.0
400.0
A-818
Max
Unit
999.999
Ohm
Max
Unit
100000.0
m/min
100000.0
rpm
Max
Unit
1000.0
%
Max
Unit
100000.0
rpm
100000.0
m/min
100000.0
rpm
Max
Unit
100000.0
rpm
100000.0
m/min
100000.0
rpm
Max
Unit
rpm
Max
Unit
300.0
mH
Max
Unit
99999.9
A/Vs
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Floating Point
immed. (ARM)
Data type
Effective
Floating Point
immed. (SLM)
Floating Point
immed. (SRM ARM)
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
PO
Floating Point
PO
Floating Point
PO
Data type
Effective
Floating Point
immed. (ARM)
Floating Point
immed. (SLM)
Floating Point
immed. (SRM)
Data type
Effective
Floating Point
RO
Data type
Effective
Floating Point
immed. (SRM)
Data type
Effective
Floating Point
immed. (ARM)
E Siemens AG 2005 All Rights Reserved
01.99
04.05
(ARM)
(SLM)
(SRM)
(ARM)
(–> 3.3)

Advertisement