Siemens SIMODRIVE 611 universal Function Manual page 871

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
08.02
02.03
A.3.3
List of permanent–magnet synchronous motors without field
weakening, build–in torque motors (1FW6, from SW 6.1)
Motor code for
permanent–
magnet
synchronous
motors without
field weakening
(1FW6)
Table A-6
Motor code for 1FW6 motors (build–in torque motors)
Order No.
(MLFB)
1FW6190–xxB07–2Axx
Unlisted motors
Note:
x:
Space retainer for the Order No.
Parameters for
unlisted motors
(1FW6l)
Table A-7
1102
1103
1104
1112
1113
1114
1115
1116
1117
1118
1122
1128
1136
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Motor
code
P1102
1862
1999
Unlisted motor: Parameters for permanent–magnet synchronous
motors without field weakening
No.
Name
Motor code number
Rated motor current
Maximum motor current
Motor pole pair number
Torque constant
Voltage constant
Armature resistance (phase value)
(rotating field inductance: L
L
)
phase
Armature inductance
Motor moment of inertia
Motor standstill current
Motor limiting current
Optimum load angle
Motor short–circuit current
A.3
n
n
M
max
rated
(100 K)
[RPM]
[RPM]
[Nm]
59
59
732.0
Parameters
Units
A(rms)
A(rms)
Nm/A
V(rms)
= 1.5 S
rotating field
mH
kgm
A(rms)
A(rms)
Degr.
A(rms)
A Lists
List of motors
I
0
rated
(100 K)
[A(rms)]
17.8
Value
1999
2
A-871