Siemens SIMODRIVE 611 universal Function Manual page 806

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
1037
DM encoder configuration
Min
Standard
0
0
... allows the encoder evaluation to be configured for a direct measuring system.
Bit 2
TTL encoder
Bit 3
Absolute encoder (EnDat interface)
Bit 4
Linear measuring system
Bit 5
Operation without direct measuring system
Bit 7
Distance-coded measuring system (from SW 4.1)
Note:
DM ––> Direct measuring system
Configuration of the indirect measuring system (IM, motor encoder) ––> refer to P1027
1038
DM serial number, low part (SRM SLM)
Min
Standard
0
0
Note:
DM ––> Direct measuring system
1039
DM serial number, high part (SRM SLM)
Min
Standard
0
0
Note:
DM ––> Direct measuring system
1040
DM pole pair number, resolver
Min
Standard
0
1
... specifies the pole pair number of the resolver used.
Examples:
Resolver
(pole pair number)
2p = 1
(1 speed)
2p = 2
(2 speed)
2p = 3
(3 speed)
2p = 4
(4 speed)
Note:
DM ––> Direct measuring system
Pole pair number for indirect measuring system (IM, motor encoder) ––> refer to P1018
1042
Encoder 1 fine resolution G1_XIST1
Min
Standard
0
11
... defines how many fine resolution bits are transferred for the PROFIBUS encoder interface.
This parameter applies for the following:
– Fine resolution for process data G1_XIST1
– Fine resolution for G1_XIST2 for reference mark or flying measurement
A-806
Max
Unit
FFFF
Hex
Max
Unit
FFFF
Hex
Max
Unit
FFFF
Hex
Max
Unit
64
Max
Unit
11
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
PO
Data type
Effective
Unsigned16
PO
Data type
Effective
Unsigned16
PO
Data type
Effective
Unsigned16
PO
Data type
Effective
Unsigned16
PO
E Siemens AG 2005 All Rights Reserved
01.99
04.05
(–> 3.3)
(–> 3.3)
(SRM SLM)
(–> 3.3)
(SRM SLM)
(–> 3.3)
(–> 3.3)