01.99
7.4
Commissioning functions
Overview
The commissioning functions and support tools help during start–up,
during service, when optimizing the drive, and troubleshooting.
The "SIMODRIVE 611 universal" control board has the following com-
missioning and help functions:
S
S
S
S
Caution
!
Setpoints entered via analog inputs (e.g. via terminals 56.x/14.x and/or
24.x/20.x) or speeds entered via PROFIBUS–DP are added when the
function generator starts.
Note:
The analog inputs can be disabled via P0607 = 0 (for terminal
56.x/14.x) or P0612 = 0 (for terminal 24.x/20.x).
Note
For a "SIMODRIVE 611 universal" control board, only 1 function
generator or 1 measuring function can be started at the same time,
i.e. either for drive A or B.
Start–up
The SimoCom U parameterization and start–up tool can, in the online
(commissioning)
mode, start the commissioning functions "function generator" and
functions and
"measuring function" with the control authority for PG/PC.
"SimoCom U" tool
Note
If online operation between SimoCom U and "SIMODRIVE 611
universal" is interrupted while a start–up function is being executed,
then this start–up function is exited, and an appropriate fault is
displayed on the display unit.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Function generator (FG)
Trace function
Test sockets (DAU1, DAU2)
Measuring function
7 Fault Handling/Diagnostics
7.4
Commissioning functions
refer to Chapter 7.4.1
(refer to Chapter 7.4.2)
refer to Chapter 7.4.3
(refer to Chapter 7.4.4)
7
7-713