Siemens SIMODRIVE 611 universal Function Manual page 130

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

4 Commissioning
4.4
Commissioning using the display and operator unit
Synchronous motor
S
Remove write protection (P0651= 1.0.)
S
Enter unlisted motor data
S
Calculate unlisted motor (set P1082 to 1)
S
Remove write protection (P0651 = 4)
S
Start to write into FEPROM (P0652 = 1),
wait until the write operation has been completed (P0652 = 0)
End
(cyclic operation)
Fig. 4-5
Commissioning using the display and operator unit (Part 3 of 3)
4-130
2
Unlisted
motor
type?
Enter the equivalent
diagram data
Reader's note
What is an unlisted motor?
A motor, which is not defined using a motor code number, and is
therefore also not in the Attachment (refer to Chapter A.3.1, A.3.4 and
A.3.5) is classified as an unlisted motor.
The motor can be supplied from Siemens or from another motor
manufacturer.
To commission an unlisted motor, the associated parameters are
required (refer under the index entry " Unlisted motor – parameters
for...".
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
from the previous page
Induction motor
S
Remove write protection (P0651= 1.0.)
S
Enter the rating plate data (type)
yes
Are the equivalent
circuit diagram data
known?
Enter the motor code (P1102 = 99)
Calculate the equivalent circuit
diagram data (set P1081 to 1)
Calculate unlisted motor
(set P1082 to 1)
E Siemens AG 2005 All Rights Reserved
01.99
no

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents