Siemens SIMODRIVE 611 universal Function Manual page 578

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

6 Description of the Functions
6.10 Parameter set changeover
Table 6-59
Parameter set–dependent parameters, continued
Parameters for parameter set
0
1
...
1417:0 1417:1 ...
1417:7 x
1418:0 1418:1 ...
1418:7 x
1421:0 1421:1 ...
1421:7 x
1426:0 1426:1 ...
1426:7 x
1428:0 1428:1 ...
1428:7 x
1451:0 1451:1 ...
1451:7 x
1453:0 1453:1 ...
1453:7 x
1500:0 1500:1 ...
1500:7
to
to
to
1521:0 1521:1 ...
1521:7
Note:
x:
The parameter is available in this operating mode
–:
The parameter is not available in this operating mode
1)
x
for spindle positioning (from SW 5.1)
How can you
toggle between
parameter sets?
6-578
Operating
mode
7
n
pos
set
x
n_x for "n_act < n_x" signal
x
n_min for "n_act < n_min" signal
x
Time constant, integrator feedback (speed controller)
x
Tolerance bandwidth for "n_set = n_act" signal
x
Threshold torque M_x (ARM, SRM)
Threshold force F_x (SLM)
x
P gain, speed controller IM (ARM)
x
Integral action time, speed controller IM (ARM)
Speed setpoint filter (ARM, SRM)
Speed setpoint filter (ARM, SRM)
x
x
Velocity setpoint filter (SLM)
Velocity setpoint filter (SLM)
Note
Only parameter set 0 is parameterized using this SimoCom U
parameterizing and start–up tool via the interactive dialog operation.
Parameter sets 1 to 7 must be parameterized using the Expert list of
SimoCom U.
You can toggle between parameter sets 0 and 7 using
the following input signals:
S
Input signal "parameter set changeover 1st input"
S
Input signal "parameter set changeover 2nd input"
S
Input signal "parameter set changeover 3rd input"
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Description
E Siemens AG 2005 All Rights Reserved
04.99
02.02
01.99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents