Siemens SIMODRIVE 611 universal Function Manual page 816

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
1117
Moment of inertia of motor (ARM SRM)
Motor mass (SLM)
Min
Standard
0.0
0.001
0.0
0.0
0.0
0.0
SRM, ARM: Moment of inertia of the motor rotor
SLM: Weight of the primary section
1118
Motor zero-speed current (SRM SLM)
Min
Standard
0.0
0.0
... corresponds to the thermally permissible continuous current when the motor is at a standstill
with an overtemperature (temperature rise) of 100 Kelvin.
1119
Series reactor inductance (ARM)
Min
Standard
0.0
0.0
1120
Current controller P gain
Min
Standard
0.0
10.0
1121
Current controller reset time
Min
Standard
0.0
3000.0
0.0
2000.0
1122
Motor current limit (SRM)
Min
Standard
0.0
0.04
1123:8
Load moment of inertia (ARM SRM)
Load weight (SLM)
Min
Standard
0.0
0.0
0.0
0.0
Additional moment of inertia (SRM, ARM) and additional weight (SLM), which is caused by cou-
pling a load to the motor. The contents of P1123:8 are added to the contents of P1117 for the
speedtorque feedforward control in induction motor operation and for the "calculate controller
data" function.
1124
Symmetrizing reference model current
Min
Standard
0.0
0.5
Note: Internal Siemens
1125
Ramp-up time 1 for V/f operation
Min
Standard
0.01
5.0
When V/f operation is selected (P1014), this is the time, in which the speed setpoint is changed
from 0 to the maximum motor speed (P1146).
1127
Voltage at f = 0 V/f operation (ARM)
Min
Standard
0.0
2.0
A-816
Max
Unit
2
9.99999
kgm
500.0
kg
2
9.99999
kgm
Max
Unit
500.0
A(rms)
Max
Unit
65.0
mH
Max
Unit
10000.0
U/A
Max
Unit
µs
8000.0
µs
8000.0
Max
Unit
500.0
A(rms)
Max
Unit
500.0
kg
2
9.99999
kgm
Max
Unit
1.0
Max
Unit
100.0
s
Max
Unit
20.0
V(pk)
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Floating Point
immed. (ARM)
Floating Point
immed. (SLM)
Floating Point
immed. (SRM)
Data type
Effective
Floating Point
PO
Data type
Effective
Floating Point
PO
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed. (ARM)
Floating Point
immed. (SRM SLM)
Data type
Effective
Floating Point
PO
Data type
Effective
Floating Point
immed. (SLM)
Floating Point
immed. (SRM ARM)
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed. (ARM)
E Siemens AG 2005 All Rights Reserved
04.05
01.99
(SRM SLM)
(ARM)
(SRM)
(–> 2.4)