Siemens SIMODRIVE 611 universal Function Manual page 251

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

08.99
05.00
Gx_XIST2
Encoder x position actual value 2 ––> Additional position actual value
Different values are entered in Gx_XIST2 depending on the function
(refer to Fig. 5-17).
S
Parking encoder?
Encoder fault?
Value x present?
Transmit absolute
value cyclically?
Fig. 5-17 Priorities for functions and Gx_XIST2
S
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Priorities for Gx_XIST2
The following priorities should be considered for values in
Gx_XIST2:
Gx_ZSW.14 = 1?
no
Gx_ZSW.15 = 1?
no
Gx_ZSW.4 = 1
or
.5 = 1
or
.6 = 1
or
.7 = 1
no
Gx_ZSW.13 = 1
no
Encoder pulses S 2
Resolution:
n:
Fine resolution
Number of bits for the internal multiplication
The fine resolution is defined via P1043/P1045 or P1042/P1044 for
the "requested value" or the "absolute value" in Gx_XIST2.
P1043
Encoder 1, fine resolution, absolute track G1_XIST2
P1045
Encoder 2, fine resolution, absolute track G2_XIST2
P1042
Encoder 1, fine resolution G1_XIST1
P1044
Encoder 2 fine resolution G2_XIST1
5 Communications via PROFIBUS DP
5.6
Net data (PKW and PZD area)
yes
Gx_XIST2 = 0
Gx_XIST2
yes
=
Error code
(refer to Table 5-24)
Gx_XIST2
yes
=
Requested value
Gx_XIST2
yes
=
Absolute value
n
5
5-251