Siemens SIMODRIVE 611 universal Function Manual page 146

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

4 Commissioning
4.7
Induction motor operation with induction motor
from the previous page
Enter the equivalent diagram data
P1117: Motor moment of inertia
P1135: Motor no–load voltage
P1136: Motor no–load current
P1137: Stator resistance, cold
P1138: Rotor resistance, cold
P1139: Stator leakage reactance
P1140: Rotor leakage reactance
P1141: Magnetizing reactance
P1142: Speed at the start of field weakening
Fig. 4-8
Commissioning induction motors without encoder (Part 2)
4-146
1
Remove write protection (P0651 = 8)
Enter the rating plate data
Are the
equivalent
yes
circuit diagram
data known?
Motor data
no
optimization
required?
yes
Calculate unlisted motor (P1082 = 1)
Save to FEPROM (P0652 = 1)
Execute POWER–ON RESET
Optimize the motor data, steps 1 to 4
(refer to Chapter 4.7.3)
Calculate unlisted motor (P1082 = 1)
Save to FEPROM (P0652 = 1)
Execute POWER–ON RESET
continue on the next
3
page
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
P1103: Rated motor current
P1119: Inductance, series reactor
P1129: cos ϕ power factor
P1130: Rated motor output
P1132: Rated motor voltage
P1134: Rated motor frequency
P1146: Maximum motor speed
P1400: Rated motor speed
no
Calculate the equivalent circuit
diagram data (P1081 = 1)
E Siemens AG 2005 All Rights Reserved
01.99