Siemens SIMODRIVE 611 universal Function Manual page 65

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
08.02
Notice
For "SIMODRIVE 611 universal", connectors X461 and X462
have been extended to an 11–pole version. This means that the signal
conductors connected to this terminal block must be re–connected to
the new (11–pole) terminal block (terminal block assignment, refer to
Fig. 1-5).
10.Download your machine data, saved under 6., into the "new" control
Warning
!
It is only permissible to install/remove a control board when the system
is in a no–voltage condition (i.e. powered–down).
If a control board is inserted or removed under voltage (with the
system powered–up), this can result in data being lost or components
being destroyed.
The ESDS measures must be observed when installing/removing the
control board.
Note
For spare control boards, a set of installation instructions are provided
which describes how the control board is replaced.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
2.1
Installing/removing control boards and modules
board using the "SimoCom U" start–up tool.
2 Installing and Connecting-Up
2
2-65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents