A Lists
A.1
Parameter list
1503:8
Time constant, speed setpoint filter 2 (ARM SRM)
Time constant, velocity setpoint filter 2 (SLM)
Min
Standard
0.0
0.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1506:8
Natural frequency, speed setpoint filter 1 (ARM SRM)
Natural frequency, velocity setpoint filter 1 (SLM)
Min
Standard
10.0
2000.0
Note:
The filter can be switched out/switched in via the "First speed setpoint filter off" input signal.
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1507:8
Damping, speed setpoint filter 1 (ARM SRM)
Damping, velocity setpoint filter 1 (SLM)
Min
Standard
0.2
0.7
Note:
The filter can be switched out/switched in via the "First speed setpoint filter off" input signal.
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1508:8
Natural frequency, speed setpoint filter 2 (ARM SRM)
Natural frequency, velocity setpoint filter 2 (SLM)
Min
Standard
10.0
2000.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1509:8
Damping, speed setpoint filter 2 (ARM SRM)
Damping, velocity setpoint filter 2 (SLM)
Min
Standard
0.2
0.7
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1514:8
Blocking frequency, speed setpoint filter 1 (ARM SRM)
Blocking frequency, velocity setpoint filter 1 (SLM)
Min
Standard
1.0
3500.0
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
A-836
Max
Unit
500.0
ms
Max
Unit
8000.0
Hz
Max
Unit
5.0
Max
Unit
8000.0
Hz
Max
Unit
5.0
Max
Unit
7999.0
Hz
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
E Siemens AG 2005 All Rights Reserved
04.05
01.99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents