! 611ue diff !
Table 6-45
List of input signals, continued
Signal name, description
Suppress fault 608 (from SW 3.1)
Fault 608 (speed controller output limited) can be suppressed/displayed using this input signal.
1 signal
Fault 608 (speed controller output limited) is suppressed
0 signal
Fault 608 is not suppressed
Note:
S
The status of the suppressed function is signaled via the PROFIBUS status signal ZSW2.8 "Sup-
pressing fault 608 active (from SW 3.1)".
S
Refer under the index entry "Output signal – suppress fault 608 active (from SW 3.1)"
S
It is also possible to suppress the fault using P1601.8 (faults which can be suppressed 2, Fault 608).
Spindle positioning on (from SW 5.1)
The function is activated using this input signal.
1 signal
Activates the "spindle positioning" function
0 signal
De–activates the function
Note:
S
Prerequisites to activate the "Spindle positioning" function
– "n–set" mode
––> P0700 = 1
S
The "spindle positioning" function is described in Chapter 6.15 (from SW 5.1).
ON/OFF 1
0/1 signal
ON
state "drive ready"
The prerequisite is that STW1.1 and STW1.2 or the input signals "operating condition /
OFF2" (Fct. No. 32) and "operating condition / OFF3" (Fct. No. 33) are also set.
The pulses remain canceled until the prerequisites for pulse enable have been fulfilled.
0 signal
OFF 1
Stop
The drive brakes along the ramp–function generator ramp.
The gating pulses of the power transistors are cancelled (pulse inhibit) if one of the follow-
ing conditions is fulfilled:
– |n
| < n (P1403)
act
or
– the pulse cancellation timer stage (P1404) has expired
Operating condition/OFF 2
1 signal
Operating condition
Prerequisite for the "drive ready" status.
0 signal
OFF 2
The motor is switched into a no–current condition and "coasts down".
Note:
The characteristics at power–on again can be defined via P1012.12.
P1012.12 = 1
Power–on inhibit for alarm and OFF 2/OFF 3
= 0
No power–on inhibit
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6 Description of the Functions
6.4
Input/output terminals of the control board
Operating
mode
Fct. No.
n–set
26
x
28
x
31 (from
x
SW 8.3)
32 (from
x
SW 4.1)
pos
PROFIBUS bit
x
STW2.8
STW1.15
x
STW1.0
x
STW1.1
6-481