Commissioning: Linear Motor With One Primary Section - Siemens SIMODRIVE 611 universal Function Manual

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

4 Commissioning
4.10 Linear motors (1FN1, 1FN3 motors)
4.10.2

Commissioning: Linear motor with one primary section

Procedure when
commissioning
using SimoCom U
!
4-172
Linear motors with a primary section (single motor) should be commis-
sioned as follows using the parameterizing and start–up tool:
Warning
The pulse enable (terminal 663) must be switched–out (de–energized)
for safety reasons before the drive is powered–up.
1. Establish online operation
Operator action: e.g. with "Commissioning – search for online
drives"
2. Configure the drive
Generally, the following is valid:
You can reach the next or the previous dialog box by pressing
"next" or "back".
– "Drive name" dialog box
– "Power module" dialog box (only if it is not automatically identi-
fied)
– "Motor selection" dialog box:
Is the linear motor included in the list of linear motors?
"Motor" field
–> Standard motor
The linear motor is not included in the list of linear motors?
––>Unlisted motor
"Motor" field
–> Enter data
The motor data should be entered after "continue".
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
"Motor type" field
–> 1FNx (linear)
"Motor type" field
–> Linear motor (SLM)