7 Fault Handling/Diagnostics
7.2
Displaying and handling faults and warnings
7.2
Displaying and handling faults and warnings
7.2.1
Display and operator control via the display and operator unit
Displaying
faults and
warnings
7-624
The segment display is automatically changed over into the alarm
mode when one or several faults or warnings occur. The faults and
warnings are output flashing on the display unit. They can be displayed
as follows:
Table 7-3
Displaying alarms on the display unit
Display example
(flashing display)
1. This is what it looks like if a fault has occurred (refer to Fig. 7-1).
S
S
S
S
2. This is what it looks like if several faults have occurred
(refer to Fig. 7-2).
S
S
S
S
Note:
By pressing the PLUS button, several faults can be
+
displayed for each additional fault.
S
S
S
S
3. This is what it looks like if a warning is present (refer to Fig. 7-3).
S
S
S
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Description
E:
it involves a fault
(Code: 1 hyphen)
1 hyphen: there is one fault present
A:
the fault is assigned to drive A
608:
is the fault number
E:
it involves several faults
(Code: 3 hyphens)
3 hyphens:
– several faults are present
– this is the first which occurred
A:
the fault is assigned to drive A
131:
is the fault number
E:
it involves an additional fault
(code: 2 hyphens)
2 hyphens:
– several faults are present
– this is an additional fault
A:
the fault is assigned to drive A
134:
is the fault number
E:
it involves a warning
(code: no hyphen)
A:
the warning is assigned to drive A
804:
is the warning number
E Siemens AG 2005 All Rights Reserved