Siemens SIMODRIVE 611 universal Function Manual page 476

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

6 Description of the Functions
6.4
Input/output terminals of the control board
Table 6-44
Overview of the input signals
Signal name, description
Inactive
Reset the fault memory
Open–loop torque controlled mode
Motor data set changeover (from SW 2.4)
0
1st input/2
1
2nd input/2
Ramp–up time zero
Integrator inhibit, speed controller
Parameter set changeover
0
1st input/2
1
2nd input/2
2
3rd input/2
Fixed speed setpoint (from SW 3.1)
0
1st input/2
1
2nd input/2
2
3rd input/2
3
4th input/2
First speed setpoint filter off
Suppress fault 608 (from SW 3.1)
Spindle positioning on (from SW 5.1)
ON/OFF 1 (from SW 8.3)
Operating condition/OFF 2
Operating condition/OFF 3
Enable inverter/pulse inhibit
Ramp–function generator enabled
Selection, parking axis
Opening the holding brake for test purposes (from
SW 4.1)
Block selection
1st input/2
2nd input/2
3rd input/2
4th input/2
5th input/2
6th input/2
Operating condition/reject traversing task
Operating condition/intermediate stop
Activate traversing task (edge)
Incremental jogging (from SW 4.1)
6-476
0
1
2
3
4
5
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Operating
mode
Fct. No.
n–set
pos
0
x
x
3
x
x
4
x
5
x
6
x
7
x
x
8
x
x
9
x
x
10
x
x
11
x
x
15
x
16
x
17
x
18
x
25
x
x
26
x
x
28
x
31 (from
x
x
SW 8.3)
32 (from
x
x
SW 4.1)
33 (from
x
x
SW 5.1)
34 (from
x
x
SW 4.1)
35
x
40
x
x
42
x
x
50
x
x
51
x
x
52
x
x
53
x
x
54
x
x
55
x
x
58
x
59
x
60
x
61
x
E Siemens AG 2005 All Rights Reserved
01.99
08.01
04.05
! 611ue diff !
PROFIBUS bit
STW1.7
STW1.14
STW2.9
STW2.10
STW2.4
STW2.6
STW2.0
STW2.1
STW2.2
STW2.3
STW2.8
STW1.15
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
STW2.7
STW1.12
SatzAnw.0
SatzAnw.1
SatzAnw.2
SatzAnw.3
SatzAnw.4
SatzAnw.5
STW1.4
STW1.5
STW1.6
PosStw.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents