6 Description of the Functions
6.4
Input/output terminals of the control board
Table 6-44
Overview of the input signals
Signal name, description
Inactive
Reset the fault memory
Open–loop torque controlled mode
Motor data set changeover (from SW 2.4)
0
1st input/2
1
2nd input/2
Ramp–up time zero
Integrator inhibit, speed controller
Parameter set changeover
0
1st input/2
1
2nd input/2
2
3rd input/2
Fixed speed setpoint (from SW 3.1)
0
1st input/2
1
2nd input/2
2
3rd input/2
3
4th input/2
First speed setpoint filter off
Suppress fault 608 (from SW 3.1)
Spindle positioning on (from SW 5.1)
ON/OFF 1 (from SW 8.3)
Operating condition/OFF 2
Operating condition/OFF 3
Enable inverter/pulse inhibit
Ramp–function generator enabled
Selection, parking axis
Opening the holding brake for test purposes (from
SW 4.1)
Block selection
1st input/2
2nd input/2
3rd input/2
4th input/2
5th input/2
6th input/2
Operating condition/reject traversing task
Operating condition/intermediate stop
Activate traversing task (edge)
Incremental jogging (from SW 4.1)
6-476
0
1
2
3
4
5
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Operating
mode
Fct. No.
n–set
pos
0
x
x
3
x
x
4
x
–
5
x
–
6
x
–
7
x
x
8
x
x
9
x
x
10
x
x
11
x
x
15
x
–
16
x
–
17
x
–
18
x
–
25
x
x
26
x
x
28
x
–
31 (from
x
x
SW 8.3)
32 (from
x
x
SW 4.1)
33 (from
x
x
SW 5.1)
34 (from
x
x
SW 4.1)
35
x
–
40
x
x
42
x
x
50
x
x
51
x
x
52
x
x
53
x
x
54
x
x
55
x
x
58
–
x
59
–
x
60
–
x
61
–
x
E Siemens AG 2005 All Rights Reserved
01.99
08.01
04.05
! 611ue diff !
PROFIBUS bit
–
STW1.7
STW1.14
STW2.9
STW2.10
STW2.4
STW2.6
STW2.0
STW2.1
STW2.2
–
–
–
–
STW2.3
STW2.8
STW1.15
STW1.0
STW1.1
STW1.2
STW1.3
STW1.4
STW2.7
STW1.12
SatzAnw.0
SatzAnw.1
SatzAnw.2
SatzAnw.3
SatzAnw.4
SatzAnw.5
STW1.4
STW1.5
STW1.6
PosStw.5