Eval. torque/power reduction PROFIBUS (ARM SRM)
Evaluation force/power reduction PROFIBUS (SLM)
Min
Standard
0.0
16384.0
0.0
16384.0
... defines the normalization of the torque/power de-rating or the force/power de-rating when
traversing with PROFIBUS-DP.
Note:
4000Hex or 16384 dec in the MomRed control board corresponds to a reduction of the percent-
age specified in P0881.
refer under the index entry "Control word MomRed"
0882
Evaluation, torque setpont PROFIBUS (ARM SRM)
Evaluation, force setpoint PROFIBUS (SLM)
Min
Standard
–16384.0
800.0
–16384.0
800.0
... defines the normalization of the torque and force setpoint when using PROFIBUS-DP.
Note:
P0882 is a percentage value referred to the rated motor torque. The parameter affects the pro-
cess data MsetExt (external torque setpoint in the input direction) and Mset (torque setpoint in
the output direction).
4000Hex or 16384 dec in the control word corresponds to the percentage entered in P0882.
refer under the index entry "control word MsollExt", "Status word Msoll"
0883
Override evaluation PROFIBUS
Min
Standard
0.0
16384.0
... defines the normalization of the override when entered via PROFIBUS-DP.
Note:
4000Hex or 16384dec in the PROFIBUS-PPO corresponds to the override in P0883 (refer
under the index entry "control word over").
0884
Position output evaluation PROFIBUS – no. of increm. (–> 4.1)
Min
Standard
1
10000
... together with P0896, defines the format for the output of positions via PROFIBUS-DP.
Note:
refer to P0896
refer under the index entry "axis couplings"
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
16384.0
%
16384.0
%
Max
Unit
16384.0
%
16384.0
%
Max
Unit
16384.0
%
Max
Unit
8388607
A.1
Parameter list
(–> 3.7)
Data type
Effective
Floating Point
immed. (SLM)
Floating Point
immed. (SRM ARM)
(–> 4.1)
Data type
Effective
Floating Point
immed. (SLM)
Floating Point
immed. (SRM ARM)
(–> 3.1)
Data type
Effective
Floating Point
immed.
Data type
Effective
Unsigned32
PO
A Lists
A
A-779