For the ramp–function generator, the following signals are used:
signals for the
S
ramp–function
generator
S
Reader's note
The signals can be entered or output as follows:
S
S
All of the input/output signals are shown and described in Chapter
6.4.3 and 6.4.6 and can be found in the Index under "Input signal..." or
"Output signal...".
Ramp–function
generation
active
n
set
RFG input
n
set
n
act
RFG output
Torque
Ramp–up
completed
n
= n
set
act
| M | < M
x
1) For an active average–value filter for the speed setpoint (P1012.8=1), a setpoint step somewhat
greater than P1426 must be used in order to clearly identify the start of a new ramp–up operation.
Fig. 6-5
Signal characteristics for the ramp–function generator
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
6.1
Operating mode, speed/torque setpoint (P0700 = 1)
Input signal
– Ramp–function generator enable
– Ramp–up time zero
– Ramp–up time zero for contr. enable (from SW 3.1)
Output signal
– Ramp–up completed
via terminals
––>
via PROFIBUS–DP
––>
Tolerance bandwidth P1426
Threshold P1428
Delay time P1427
P1427
Delay time P1429
6 Description of the Functions
refer to Chapter 6.4.2 or 6.4.5
refer to Chapter 5.6.1
P1427
from here onwards, | M | < Mx evaluation
6
P1426
6-335