Technical data

11.3 Transportation and storage conditions for SIMOTION C

11.3
Transportation and storage conditions for SIMOTION C
With regard to transportation and storage conditions, the SIMOTION C surpasses the
requirements specified in IEC 1131, Part 2. The following conditions apply to modules that are
transported and stored in the original packaging.
Table 11-17 Transportation and storage conditions for SIMOTION C
Type of condition
Free fall
Temperature (transport)
Atmospheric pressure
Relative humidity (transport)
11.4
Mechanical and climatic environmental conditions for operation of the
SIMOTION C
Use conditions
The SIMOTION C is designed for use in a stationary, weather-protected installation.
The SIMOTION C satisfies the operating conditions for Class 3C2 in accordance with DIN EN
60721 3-3 (operating locations with high traffic densities and in the immediate vicinity of
industrial equipment with chemical emissions).
The SIMOTION C must not be used in the following locations without additional measures
being taken:
● Locations with a high percentage of ionizing radiation
● Locations with severe operating conditions, e.g. due to:
– Dust accumulation
– Corrosive vapors or gases
● Installations requiring special monitoring, such as:
– Elevator installations
– Electrical installations in highly sensitive areas
An additional measure for the use of the SIMOTION C could be installation in a cabinet, for
example.
170
Permissible range
≤ 1 m
From - 40° C to + 70° C
1,060 to 700 hPa (corresponds to an altitude of up to 3000 m)
5% to 95%, without condensation