Siemens SIMODRIVE 611 universal Function Manual page 138

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

4 Commissioning
4.6
Parameters for hardware, operating mode and clock cycles
Table 4-4
Hardware parameters
No.
Name
1102
Motor code number
The motor code number defines the connected motor.
Note:
S
The motor code of the existing motor is located in the following lists:
– for rotating synchronous motors (SRM)
– for permanent–magnet synchronous motors with field–
weakening (1FE1 motor, PE spindle, from SW 3.1)
– for linear synchronous motors (SLM)
– for induction motors (ARM)
S
At the first commissioning and at each POWER ON, the motor data are pre–assigned
according to the entered motor code (Exception: unlisted motor).
S
For unlisted motors, the parameters must be manually assigned (refer to Chapter A.3).
1106
Power module code number
The power module code number defines the power module used.
Note:
S
The power module code can be determined from a list (refer to Chapter A.2).
S
It is not necessary to select power modules with automatic identification.
1006
IM encoder code number
The encoder code number describes the connected encoders.
Note:
S
The encoder code number can be determined from a list (refer to Chapter A.4).
S
At the first commissioning and at each POWER ON the encoder data are pre–assigned
corresponding to the entered encoder code number (Exception: Unlisted encoder).
S
For unlisted encoders, the parameters must be manually assigned (refer to Chapter A.4).
4-138
Power module (Order No.) Automatic identification?
S
6SN112V–VVVVV–VVV0
S
from 6SN112V–VVVVV–VVV1
V: Space retainer for the Order No.
After the first commissioning, a value is in P1106 (power module code
No.) which corresponds to the particular power module.
An automatic power module identification routine is executed each time
the control board runs up. In this case, the value in P1106 is compared
with the value of the power module identified in P1110.
If the values are not the same, there is an error condition, and an ap-
propriate fault message is signaled.
Parameters
Min.
0
0
0
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
No automatic identification
Automatic identification
Standard
Max.
0
FFFF
––> refer to Chapter A.3.1
––> refer to Chapter A.3.2
––> refer to Chapter A.3.4
––> refer to Chapter A.3.5
0
FFFF
0
65 535
E Siemens AG 2005 All Rights Reserved
10.99
01.99
Units
Effective
PO
PO
PO