Siemens SIMODRIVE 611 universal Function Manual page 776

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
0872
Option module type
Min
Standard
... displays which option module was identified when the control module was powered-up.
0
no option module
1
Optional TERMINAL module, Order No. (MLFB): 6SN1114–0NA00–0AA0
2
Option module PROFIBUS-DP1
with PROFIBUS-ASIC SPC3, Order No. (MLFB): 6SN1114–0NB00–0AA0
3
Option module PROFIBUS-DP2 (from SW 3.1)
with PROFIBUS ASIC DPC31 without PLL, Order No. (MLFB): 6SN1114–0NB00–0AA1
4
Option module PROFIBUS-DP3 (from SW 3.1)
with PROFIBUS ASIC DPC31 with PLL, Order No. (MLFB): 6SN1114–0NB01–0AA0
253
CAN – option module, Robox company
255
Third-party module corresponding to the published interface spec. (from SW 4.1)
0873
Option module version
Min
Standard
... displays the version of the respective option module.
0875
Expected option module type
Min
Standard
0
0
... displays which option module is expected due to the parameters set.
During first startup, the parameter is automatically set according to P0872 (option module type).
Note:
Disable the communication or the "DP slave 611U":
1-axis module
––> with P0875 = 0 from drive A, the "DP slave 611U" is disabled
2-axis module
––> with P0875 = 0 from drive B, communication with drive B is disabled
––> with P0875 = 0 in both drives, the "DP slave 611U" is disabled
This allows, for example, "disturbing" slaves to be temporarily disabled when commissioning
other nodes (refer to the index entry "Commissioning PROFIBUS-DP").
A-776
Max
Unit
Max
Unit
Hex
Max
Unit
255
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned16
RO
Data type
Effective
Unsigned16
RO
Data type
Effective
Unsigned16
PO
E Siemens AG 2005 All Rights Reserved
04.05
01.99