Siemens SIMODRIVE 611 universal Function Manual page 466

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

6 Description of the Functions
6.3
Axis couplings (from SW 3.3)
Input/output
signals (refer to
Chapter 6.4)
6-466
The following signals are used for the function "torque setpoint cou-
pling":
S
Input signals
(refer under index entry "Input signal, digital – ...")
– Input signal "open–loop torque controlled operation"
––> using an input terminal with function number 4
––> using the PROFIBUS control signal "STW1.14"
– Input signal "external torque setpoint"
––> using the PROFIBUS control signal "MsollExt"
– Input signal "torque limit reduction"
––> using the PROFIBUS control signal "MomRed"
S
Output signals
(refer under the index entry, "Output signal, digital – ...")
– Output signal, "in synchronism"
––> using an output terminal with function number 71
––> using the PROFIBUS status signal "PosZsw.3"
– Output signal "open–loop torque controlled operation"
––> using the PROFIBUS status signal "ZSW1.14"
– Output signal "smoothed torque setpoint"
––> using the PROFIBUS status signal "Msoll"
– Output signal "smoothed torque–generating current Iq"
––> using the PROFIBUS status signal "IqGl"
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
E Siemens AG 2005 All Rights Reserved