Siemens SIMODRIVE 611 universal Function Manual page 819

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
04.05
! 611ue diff !
1151
Reset time flux controller (ARM)
Min
Standard
0.0
10.0
1160
Threshold speed flux sensing (ARM)
Min
Standard
200.0
1500.0
1161
Fixed DC link voltage
Min
Standard
0
0
... a fixed DC link voltage can be entered.
> 0
Fixed DC link voltage, the measurement in P1701 (DC link voltage) is inactive
0
The measurement in P1701 is active
The fixed DC link reference is calculated in instead of the measurement:
– DC link adaption
– Flux sensing (ARM)
– Field weakening and stall torque (ARM)
Note:
The DC link is measured in the I/R module, and is transferred as analog signal to the
"SIMODRIVE 611 universal" via the unit bus for evaluation.
1162
Min. DC link voltage
Min
Standard
0
0
... defines the permissible DC link voltage lower limit. Fault 616 is output if this limit is fallen be-
low.
1163
Max. DC link voltage
Min
Standard
0
800
... defines the permissible DC link voltage upper limit. Fault 617 is output if this limit is ex-
ceeded.
1164
Hysteresis, DC link monitoring
Min
Standard
0
50
... defines the hysteresis for the DC link voltage monitoring. This parameter refers to parameter
1162..
1170
Pole pair width (SLM)
Min
Standard
0.0
72.0
The pole pair width of a linear drive corresponds to the length from a north and south pole of
the magnet.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
500.0
ms
Max
Unit
100000.0
rpm
Max
Unit
700
V(pk)
Max
Unit
800
V(pk)
Max
Unit
800
V(pk)
Max
Unit
600
V(pk)
Max
Unit
1000.0
mm
A.1
Parameter list
Data type
Effective
Floating Point
immed. (ARM)
Data type
Effective
Floating Point
immed. (ARM)
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
immed.
(–> 8.1)
Data type
Effective
Unsigned16
immed.
Data type
Effective
Floating Point
PO
(SLM)
A Lists
A
A-819

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents