Siemens SIMODRIVE 611 universal Function Manual page 49

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
10.99
! not 611u !
Table 1-6
Overview of the drive–specific terminals, continued
Terminals
Drive A
Drive B
No.
Desig-
No.
Desig-
nation
nation
Terminals for the analog inputs and digital inputs/outputs (X453, X454)
X453
X454
56.A
X453.1
56.B
X454.1
14.A
X453.2
14.B
X454.2
24.A
X453.3
24.B
X454.3
20.A
X453.4
20.B
X454.4
65.A
X453.5
65.B
X454.5
9
X453.6
9
X454.6
I0.A
X453.7
I0.B
X454.7
I1.A
X453.8
I1.B
X454.8
1) I: Input; S: Supply; DI: Digital input
2) Can be freely parameterized
All of the digital inputs are de–bounced per software. For the signal detection, this results in a delay time
of between 1 and 2 interpolation clock cycles (P1010).
3) I0.x is internally hard–wired to the position sensing function where it acts almost instantaneously.
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1.4
"SIMODRIVE 611 universal E" control board
Function
Function
Function
Type
Type
Type
1)
1)
1)
Connector type:
Max. conductor cross–section for finely–stranded or solid conduc-
2
tors: 0.5 mm
none
none
none
none
Controller enable
I
drive–specific
Enable voltage
S
(+24 V)
2)
Digital input 0
DI
Fast
3)
input
2)
Digital input 1
DI
1 Product Overview
Technical data
Technical data
Technical data
10–pin conn. strip
Typ. current consumption:
6 mA at 24 V
Signal level (incl. ripple)
High signal level: 15 V to 30 V
Low signal level: –3 V to 5 V
Electrical isolation:
Ref. is T. 19/T. M24
Reference:
Terminal 19
Maximum current
(for the total group):
500 mA
Note:
The enable voltage (terminal 9) can
be used to supply the enable signals
(e.g. controller enable).
Voltage:
24 V
Typ. current consumption:
6 mA at 24 V
Signal level (incl. ripple)
High signal level: 15 V to 30 V
Low signal level: –3 V to 5 V
Electrical isolation:
Ref. is T. 19/T. M24
Note:
Note:
S
The parameterization of the input
terminals and the standard as-
signment is described in Chapter
6.4.2.
S
An open–circuit input is
interpreted as 0 signal.
1
1-49

Advertisement

Table of Contents
loading

This manual is also suitable for: