Commissioning 1Fe1 Motors - Siemens SIMODRIVE 611 universal Function Manual

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
02.03
10.99
4.8
Permanent–magnet synchronous motor with field–weakening (PE spindle)
4.8.2

Commissioning 1FE1 motors

General
The following questions must be positively responded to before com-
information on
missioning 1FE1 motors:
commissioning
S
1FE1 motors
S
S
Commissioning
1FE1 motors are commissioned using the SimoCom U parameterizing
1FE1 motors with
and start–up tool as follows:
SimoCom U
1. Establish online operation
2. Configure the drive
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Are all of the prerequisites for commissioning checked and
were the points in the checklist for commissioning checked (refer to
Chapter 4.1)?
Is the motor used a standard or an unlisted motor?
– Standard motor?
The motor is in a list of permanent–magnet synchronous motors
with field weakening, and has an allocated motor code (refer to
Chapter A.3.2)?
When commissioning, the motor used is selected from a list.
– Unlisted motor?
The motor is not included in the list of permanent–magnet
synchronous motors with field–weakening, and it does not have
a motor code (refer to Chapter A.3.2)?
When commissioning, the data of the motor used must be avail-
able and must be manually entered.
The data required can be found in the table under the index entry
"Unlisted motor – parameters for PE spindle".
Are the motor and encoder already mounted and ready to be pow-
ered up?
Operator action: e.g. with "Commissioning – search for online
drives"
Generally, the following is valid:
You can reach the next or the previous dialog box by pressing
"next" or "back".
– "Drive name" dialog box
– "Power module" dialog box (only if it is not automatically identi-
fied)
– "Motor selection" dialog box for standard motors:
"Motor" field
–> Standard motor
––> select the motor used
––> continue with the "measuring system/encoder" dialog box
4 Commissioning
"Motor type" field
–> 1FT6, 1FK6, 1FE1, 1FW6 (synchronous)
4
4-155

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents