Siemens SIMODRIVE 611 universal Function Manual page 821

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

01.99
04.05
! 611ue diff !
1201:8
Current setpoint filter type
Min
Standard
0
0
... specifies the type of the 4 current setpoint filters.
Bit 0
Filter 1
= 1
Bandstop (filter parameters: P1210:8, P1211:8, P1212:8)
= 0
Low pass (filter parameters: P1202:8, P1203:8)
Bit 1
Filter 2
= 1
Bandstop (filter parameters: P1213:8, P1214:8, P1215:8)
= 0
Low pass (filter parameters: P1204:8, P1205:8)
Bit 2
Filter 3
= 1
Bandstop (filter parameters: P1216:8, P1217:8, P1218:8)
= 0
Low pass (filter parameters: P1206:8, P1207:8)
Bit 3
Filter 4
= 1
Bandstop (filter parameters: P1219:8, P1220:8, P1221:8)
= 0
Low pass (filter parameters: P1208:8, P1209:8)
Bit 15
Bandstop, transformation type (from SW 3.3)
= 1
Z transformation
= 0
Bilinear transformation (standard)
Note:
Before parameterizing the filter type, the appropriate filter parameters must be assigned.
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1202:8
Natural frequency current setp. filter 1
Min
Standard
0.0
2000.0
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1203:8
Damping, current setp. filter 1
Min
Standard
0.05
0.7
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1204:8
Natural frequency current setp. filter 2
Min
Standard
0.0
0.0
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1205:8
Damping, current setp. filter 2
Min
Standard
0.05
1.0
Note:
The current setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
800F
Hex
Max
Unit
8000.0
Hz
Max
Unit
5.0
Max
Unit
8000.0
Hz
Max
Unit
5.0
A.1
Parameter list
Data type
Effective
Unsigned16
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed.
A Lists
A
A-821