PROFIBUS selector switch operating mode
Min
Standard
This parameter cannot be changed and corresponds to P0700.
0
Drive inactive
1
Closed-loop speed controlled operation
0x8000 positioning mode
0944
Fault message counter
Min
Standard
This parameter corresponds to the fault message counter. It is incremented each time that the
fault buffer changes.
This means that it can be ensured that the fault buffer can be consistently read-out
Note:
This parameter is reset at POWER ON.
refer to the index entry "PROFIBUS-DP – evaluate faults".
0945:65
Fault code
Min
Standard
The fault code, i. e. the number of the fault which occurred, is entered in this parameter.
The faults which occurred are entered as follows into the fault buffer:
first fault which has occurred ––> parameter with index 1 (with index 0 for the PROFIdrive pro-
file)
To
eighth fault which has occurred––> parameter with index 8 (with index 7 for the PROFIdrive
profile)
Note:
The following is associated with a fault: Fault code (P0945:65), fault number (P0947:65), fault
time (P0948:65) and fault value (P0949:65).
For "reset fault memory" the fault code, previously entered into P0945, is shifted by 8 indices.
The description of the faults, how they can be acknowledged as well as a list of all the faults is
provided in Section "Fault handling/diagnostics".
This parameter is reset at POWER ON.
If this parameter is read via non-cyclic communication (PROFIdrive), then the indices have
been shifted. Index 1 corresponds to Index 0 (etc.) in the description of the PROFIdrive profile.
refer to the index entry "PROFIBUS-DP – evaluate faults".
0946:901 Fault code list
Min
Standard
This parameter contains the fault code list.
In the fault code list, every fault code, defined in the unit, is assigned a fault number.
Note:
The fault number is a consecutive number. The actual value is coded in the fault code to indi-
cate which fault has occurred.
If this parameter is read via non-cyclic communication (PROFIdrive), then the indices have
been shifted. Index 1 corresponds to Index 0 (etc.) in the description of the PROFIdrive profile.
This means that here, the fault code (e. g. 130) cannot be found in the sub-index (in the exam-
ple 64) corresponding to the fault number, but instead in the following sub-index (in the example
65).
refer to the index entry "PROFIBUS-DP – evaluate faults".
E Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Max
Unit
Hex
Max
Unit
Max
Unit
Max
Unit
A.1
Parameter list
Data type
Effective
Unsigned16
RO
(–> 6.1)
Data type
Effective
Unsigned16
RO
Data type
Effective
Unsigned16
RO
(–> 6.1)
Data type
Effective
Unsigned16
RO
A Lists
A
A-787