Siemens SIMODRIVE 611 universal Function Manual page 840

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
1605
Timer n controller at stop
Min
Standard
20.0
200.0
... specifies how long the speed controller or velocity controller output can be at its limit without
fault 608 being output.
Important:
If P1605 < P1404, then regenerative braking can be exited with fault 608, whereby the drive
then "coasts down".
Note: refer to the index entry "Monitoring functions"
1606
Threshold n controller at stop
Min
Standard
0.0
30.0
0.0
500.0
0.0
90000.0
... specifies up to which speed or velocity the torque setpoint or force setpoint monitoring is ac-
tive, i. e. up to this value, fault 608 can be output (speed controller at the endstop).
Note:
In the case of PE spindles (P1015=1), the standard assignment will be as with ARM (30.0
rpms).
refer under index entry "Monitoring functions"
1607
Shutdown limit motor temperature
Min
Standard
0
155
... defines the shutdown limit for the motor temperature monitoring without pre-alarm.
When this temperature threshold is exceeded, the drive is shut down, the pulses canceled and
fault 613 output.
Note:
The monitoring function can be enabled/disabled via P1601.13.
The temperature monitoring functions with/without pre-alarm (P1602 + P1603 or P1607) are not
mutually restricted, i. e. P1607 < P1602 is permissible.
Refer under the index entry "Monitoring functions".
1608
Fixed temperature
Min
Standard
0
0
If a value > 0 is entered, then the rotor resistor is adapted, temperature-dependent, with this
fixed temperature.
Note:
The measured temperature is then no longer monitored and parameters 1602, 1603 and 1607
are then no longer effective.
A fixed temperature can, e. g. be required, if a motor does not have a temperature sensor.
Thus, e.g. the temperature monitoring of linear motors is disabled for the case where the moni-
toring is realized via an external PLC.
Refer under the index entry "Monitoring functions".
1610
Diagnostic functions
Min
Standard
0
1
0
0
Note: Internal Siemens
A-840
Max
Unit
10000.0
ms
Max
Unit
100000.0
rpm
100000.0
m/min
100000.0
rpm
Max
Unit
_C
200
Max
Unit
_C
200
Max
Unit
3
Hex
3
Hex
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Floating Point
immed.
Data type
Effective
Floating Point
immed. (ARM)
Floating Point
immed. (SLM)
Floating Point
immed. (SRM)
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
immed.
Data type
Effective
Unsigned16
PO
Unsigned16
PO
E Siemens AG 2005 All Rights Reserved
04.05
01.99
(ARM)
(SRM SLM)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents