Jogging Operation - Siemens SIMODRIVE 611 universal Function Manual

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

6 Description of the Functions
6.2
Positioning mode (P0700 = 3, from SW 2.1)
6.2.9

Jogging operation

Description
Changing over
into the jogging
mode
Input signal
"Jogging 1 ON/Jogging 1 OFF"
24 V
Input signal
"Jogging 2 ON/Jogging 2 OFF"
24 V
Fig. 6-22 Jogging: Via velocity or incrementally
Input signal "jogging 1 ON/jogging 1 OFF"
Input signal "jogging 2 ON/jogging 2 OFF"
Fixed setpoint, jogging 1: P0108
1)
Accelerating and braking along the
maximum acceleration/deceleration
characteristic (P0103/P0104)
Fixed setpoint, jogging 2: P0109
Fig. 6-23 Accelerating and braking when jogging
6-406
Closed–loop speed controlled traversing is made possible when jogging
in the "positioning" mode. Jogging is executed using the input signal
"Jogging 1, 2 ON" .
The jogging mode can be selected using the input signal "jogging incre-
mental" (refer to Fig. 6-22):
S
Jogging via velocity (standard)
S
Jogging via velocity and increments (from SW 4.1)
Input signal "incremental jogging"
P0108
P0108
P0109
P0109
1 signal
0 signal
1 signal
0 signal
Speed n
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
S
Via velocity
Jog 1
S
P0122
Via velocity and
increments
S
Via velocity
Jog 2
S
P0123
Via velocity and
increments
1)
1)
1)
E Siemens AG 2005 All Rights Reserved
08.01
01.99
! not 611ue !
t
t
t
1)