Siemens SIMODRIVE 611 universal Function Manual page 50

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

1 Product Overview
1.4
"SIMODRIVE 611 universal E" control board
Table 1-6
Overview of the drive–specific terminals, continued
Terminals
Drive A
Drive B
No.
Desig-
No.
nation
O0.A
X453.9
O0.B
O1.A
X453.10 O1.B
Note:
S
The power switched via these outputs is supplied via terminals P24/M24 (X431). This must be
taken into account when dimensioning the external supply.
S
The digital outputs only "function" if an external power supply is available (+24 V, T. P24/M24).
1) DO: Digital output
2) Can be freely parameterized
The digital outputs are updated in the interpolation clock cycle (P1010). This is supplemented by a
hardware–related delay time of approx. 200 µs.
1-50
Function
Function
Function
Desig-
nation
X454.9
Digital output 0
X454.10 Digital output 1
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Type
Type
Type
1)
1)
1)
2)
DO
Rated current per output:
Max. current per output:
Voltage drop, typical:
250 mV at 500 mA
Short–circuit proof
Short–circuit proof
2)
DO
Note:
Parameterization of the output termi-
nals as well as the standard assign-
ment is described in Chapter 6.4.5.
E Siemens AG 2005 All Rights Reserved
10.99
01.99
! not 611u !
Technical data
Technical data
Technical data
500 mA
600 mA