Siemens SIMODRIVE 611 universal Function Manual page 764

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

A Lists
A.1
Parameter list
0656
Image, output signals, Part 1
Min
Standard
... is an image of selected output signals (terminal and PROFIBUS signals).
Bit 0
Ready to power-on/not ready to power-on
Bit 1
Ready or no fault
Bit 2
Status controller enable
Bit 3
Fault present/fault not present
Bit 4
No OFF 2 present/OFF 2 present
Bit 5
No OFF 3 present/OFF 3 present
Bit 6
Power-on inhibit/no power-on inhibit
Bit 7
Alarm present/no alarm present
Bit 8
n_set = n_act <––> no following error/following error
Bit 9
Control request/control not possible
Bit 10 Comparison value reached <––> reference position reached
Bit 11 Reference point set/no reference point set
Bit 12 Setpoint acknowledgement (edge)
Bit 13 Function generator active <––> drive stationary/drive moves
Bit 14 Torque-controlled operation <––> External block change
Bit 15 Spindle positioning on <––> request passive referencing
Note:
<––>: Signal in "speed/torque setpoint" <––> in "positioning"
/: 1 signal/0 signal
0657
Image, output signals, Part 2
Min
Standard
... is an image of selected output signals (terminal and PROFIBUS signals).
Bit 0
Status, parameter set, 1st output
Bit 1
Status parameter set, 2nd output
Bit 2
Status parameter set, 3rd output
Bit 3
First speed setpoint filter inactive
Bit 4
Ramp-function generator inactive
Bit 5
Open holding brake
Bit 6
Integrator inhibit, speed controller
Bit 7
Parking axis selected
Bit 8
Suppress fault 608 active
Bit 9
Actual motor, 1st signal
Bit 10 Actual motor, 2nd signal
Bit 11 Motor being changed-over <––> angular incremental encoder handwheel evaluation,
bit 0 (from SW 8.1)
Bit 12 Angular incremental encoder handwheel evaluation, bit 1 (from SW 8.1)
Bit 13 Angular incremental encoder handwheel active (from SW 8.1)
Bit 14 Block processing inactive
Bit 17 MDI active (from 7.1)
Bit 18 Status, block selection, 1st output
Bit 19 Status block selection, 2nd output
Bit 20 Status, block selection, 3rd output
Bit 21 Status, block selection, 4th output
Bit 22 Status block selection, 5th output
Bit 23 Status, block selection, 6th output
Note:
<––>: Signal in "speed/torque setpoint" <––> in "positioning"
A-764
Max
Unit
Hex
Max
Unit
Hex
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
! 611ue diff !
Data type
Effective
Unsigned32
RO
Data type
Effective
Unsigned32
RO
E Siemens AG 2005 All Rights Reserved
04.05
01.99